Tikkurila Everal High Gloss 90

Alkyd gloss for interior and exterior surfaces 

High solids gloss with excellent opacity, formulated to provide low sag and drip characteristics.

New and previously painted interior and exterior trims including doors, skirting, windows where a solid solvent high gloss finish is required. Everal high gloss is suitable for use on metal surfaces.

Can be used on interior and exterior surfaces which require a high gloss finish.


KiiltäväMatta
Tool: rollerTool: sprayApplication conditions
The coverage of the paint on rough surfaces
8
m2/l
The coverage of the paint on smooth surfaces
12
m2/l

Versatile application

Suitable for painting e.g. furniture, windows, fences, ladders, railings, masts, racks and other wood and metal elements.

Decoration and protection

The enamel can be tinted in many attractive colours and it is resistant to mechanical damage.


Tikkurila Oyj
PRODUCT DATA SHEET
15.05.2015
 

Everal High Gloss [90]

Description
Alkyd gloss for interior and exterior surfaces.
Product features

High solids gloss with excellent opacity, formulated to provide low sag and drip characteristics.

For interior and exterior painting of metal, zinc metal, wood and wooden like surfaces, resistant to mechanical damage.  
Recommended uses
Product designed for painting of: furniture, doors, windows, fences, ladders, balustrades, poles, racks, etc.

TECHNICAL DATA
The paint is full-gloss Tool: roller Tool: spray Application conditions
The coverage of the paint on rough surfaces
8
m2/l
The coverage of the paint on smooth surfaces
12
m2/l
Base paints
A and C
Colour Range
Colours from tinting system Tikkurila Symphony, NCS and RAL.
Gloss grade
Full-gloss
Coverage

8-12 m2/l, depending on the type and absorption of the surface.

Can sizes
0.9 l; 2.7 l; 9 l
Application method
Brush, rollers or pneumatic spray (spray application can be used only on installations in which there are used laws in case of emission standards). 
Drying times
Dust dry after 4 hours. Touch dry after 6-7 hours. Application of the following coats after 16 hours (temperature +23°C, relative air humidity 50%). Notice: in case of intensive colours drying time of enamel can get longer.
Weather resistance
Very good
Scrub resistance
Good
Light resistance
Good
Heat resistance
Max. +100°C, in higher temperatures the surface has a tendency to yellowing.
Solids volume
Min. 52% weight
Density
Base A – approx. 1.155 g/cm3, Base C – approx. 1.055 g/cm3.

APPLICATION DETAILS
Application conditions
Painting works carried out at a temperature from +5°C to +25°C and relative air humidity below 80%. Temperature of painted surface should be min. 3°C higher than the dew point temperature.
Preparation
Surface must be clean, dry and free from grease, dust and loose paint elements.

Unpainted surfaces:
Wood and wooden like surfaces should be primed before application of enamel with Tikkurila Everal Primer. Exterior surfaces should be primed with Tikkurila Valtti Super Guard (or Valtti Base+). Steel and iron surfaces should be primed with anti-corrosive primer Tikkurila Everal Corrostop and then with enamel as a finish coat.

Previously painted surfaces:
Wood and wooden like surfaces covered with mould, algae etc. should be painted with special agent which will remove microorganisms, then rinse with water and let to dry. Remove all loose, old paint elements and sand the surface, remove dust and degrease. Before the application of enamel surface should be primed with Tikkurila Everal Primer. In case of repainting of the surface in dark colour and in case of application of colours which have a low hiding power, it is recommended to use primer tinted to colour similar to enamel colour. Metal surfaces should be cleaned from rust with metal brush to ST2 clean level according to PN ISO 8501-1. Remove dirt, water-diluted salts, grease and oils with Tikkurila Panssaripesu Cleaning Agent. Rinse with water and let to dry. Old, glossy surfaces should be matt down before painting. Prime unpainted metal surfaces with Tikkurila Everal Corrostop. Zinc surfaces should be sand down and then primed with Tikkurila Everal Metal Primer.

Notice:
All surfaces painted with primers: Tikkurila Everal Primer, Tikkurila Everal Corrostop, Tikkurila Everal Metal Primer and impregnant Tikkurila Valtti Super Guard, can be painted after 24 hours from application of the last coat.

Diluting
Tikkurila Everal Thinner 1050 or white spirit.
Application
Before painting stir paint thoroughly. For spray application thin product with Tikkurila Everal Thinner 1050 by adding 10-20% of thinner volume. Apply 1-3 coats, depends on the condition of the surface. It is recommended to use ANZA painting tools.
Cleaning of tools
Before washing tools should be thoroughly wiped in order to remove as much paint. Clean tools with Tikkurila Everal Thinner 1050 or white spirit immediately after the completion of the work.
EU VOC 2004/42/EC-limit value
Cat. A/d. Acceptable content VOC since 2010r. - 300 g/l. Product contain below: 300 g/l VOC

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Contains: hydrocarbons, C9-C11, n-alkanes,isoalkanes,cyclics,<2% arom. Notice! Flammable liquid and vapor. May cause drowsiness and dizziness. Contains ethyl methyl ketoxime and cobalt bis(2-ethylhexanoate). May produce an allergic reaction. Keep out of reach of children. If medical advice is needed, have product container or label at hand. Avoid breathing vapor. In case of inadequate ventilation wear respiratory protection. Keep away from sparks and open flames. - No smoking. Material Safety Data Sheets available on customer request.
Safety data sheet

ENVIRONMENTAL and WASTE DISPOSAL
Empty containers and packaging containing residues of paints pass to the point for the collection of this waste. Detailed information on the possibility of collecting waste from your local Municipal Office.
TRANSPORT
Transport and storage tightly closed containers in temp. from +5°C to +25°C, storage in dry and ventilated areas. Protect paint from frost. Product in a package of capacity under 450l, because they meet the requirements of paragraph 2.2.3.1.5 are not under a ADR/RID regulation.
FURTHER INFORMATION
NOTICE: the degree of gloss grade can be affect by the intensity of the chosen color and thickness of the coating.
-

Paint calculator

Treated surface area
m
m
Paint coverage, when surface is...
1L =
1L =
Treatment for surface
Number of coats
Product consumption, when surface is...
litres
litres
Error!

Instructions

Consumption varies depending on the surface to be treated and its condition. Absorption is affected e.g. by the surface roughness, moisture content level of timber and porosity. For example, log surface that has been untreated for a long time takes a lot more wood finish than a new surface to be treated.

When calculating the consumption, note that the consumption for round logs is 1.5 times higher than normal. Please also note the corner joints in the surface area.

Rounding up

As the filling rate is usually 90% (space for tinting), it is good to round up the liter amounts and reserve enough of the product so that the work is not interrupted unnecessarily, and colour will be even.